Página Inicial CNEA Laboratorio TANDAR Página Inicial TANDAR Historia del acelerador TANDAR Web interno Web mail
Inicio » Actividades I+D > Publicaciones 2014 > Revisiting the 7Li(p,n)7Be reaction near...
acta de conferencia
"Revisiting the 7Li(p,n)7Be reaction near threshold"
María S. Herrera, Gustavo A. Moreno and Andrés J. Kreiner
Proc. of the "15th International Congress on Neutron Capture Therapy" (15-ICNCT), Tsukuba, Japan, September 10-14, 2012. Ed. by A. Matsumura, T. Yamamoto, K. Nakai and H. Kumada
Appl. Radiat. Isot. 88 (2014) 243-246
Abstract
In this work we review all the available experimental neutron data for the 7Li(p,n) reaction near threshold which is necessary to obtain an accurate source model for Monte Carlo simulations in Boron Neutron Capture Therapy. Scattered published experimental results such as cross sections, differential neutron yields and total yields were collected and analyzed, exploring the sensitivity of the fitting parameters to the different possible variables and deriving a consistent working set of parameters to evaluate the neutron source near threshold.
SUBGERENCIA TECNOLOGIA Y APLICACIONES DE ACELERADORES
Contacto
Av. Gral Paz y Constituyentes, San Martín, Pcia. de Buenos Aires, Argentina
Tel: (54-11) 6772-7007 - Fax: (54-11) 6772-7121